Electric Fire Pump Controller  
   HOME  ::
   
 
Standard Options
4 Pressure Components rated for up to 300 PSI and for fresh water applicaitons.  (standard)   R2 Aux Relay 3 poles wired to terminals Customer to specify function
5 Pressure Components rated for up to 600 PSI for fresh water applications   R5 Includes NO & NC inst. contacts for load shed and time delay start
6 Pressure Components rated for up to 300 PSI for salt water   R7 Loadshed w/time delay for cont. w/ATS
7 Pressure Components rated for up to 600 PSI for salt water    S1 Pump Failure to Start Alarm Contacts & Indicator Light
E6 Paperless Pressure Recorder with RS232 for downloads.  Records pressure data for last 7 day period   S2 Pump Overload Alarm Contacts & Indicator Light
3R Type 3R Enclosure for Outdoor, raintight aplications.  Extra Gasketing on Doors and other openings to prevent entry of rain   S3 Extra Phase Reversal Alarm Contacts for Remote Annunciation
4P Type 4 Enclosure for Raintight applications.  This powder coat painted steel enclosure resists the entry of rain and hose directed water.   S4 Remote Low Pressure Alarm Contacts
4X Type 4X Enclosure for Raintight and corrosive resistant applications.  This 304 stainless steel enclosure resists the entry of rain and hose directed water.   S5 Extra Pump Run NO & NC
12 Type 12 Enclosure for Indoor, dust tight aplications.  Extra Gasketing on Doors and other openings to prevent entry of Dust.   S6 Extra Power Failure NO & NC
      S7 Extra Power Available NO & NC
D1 Italian Nameplate   S8 Low Voltage Alarm 90% NO & NC
D2 Dutch Nameplate   S81 Low Reservior Light & NO & NC
D3 German Nameplate   S82 High Reservior Light & NO & NC
D4 French Nameplate   S84 Reserved
D5 Spanish Nameplate   S85 Low Room Temp Light & NO & NC,  (Includes Option V Room Temp Switch)
D6 Portugese Nameplates      
         
G Built In Alarm Panel provides   V Pump Room Temperature Switch
H1 Pump Operating Light - LED Standard on all D-Series units built after 3/1/06   W Aux. Contact for remote indications of transfer switch position
H2 Other Light Functions, Customer to Specify function of light.   W1 Wkly Test Timer w/drain Solenoid Valve
H3 Light package   Y  CE Marking
J, J21, J22 Lockout Relay - Interface relay to lock out a conroller from operation. Used with Low Suction Controls and Additive Pump Control options   M & P2  Tropicalization
K Control Fuse, 1 Ampere fuse for control circuit being used outside of the controller enclosure.      
  Sequence Start (Standard)      
L Series Pumping Controls      
M Anti-Condensation Space Heaters with Transformer      
N Space heater only 100 watt, 120 V      
N1 Space heater only 100 watt, 240 V.      
P1 Thermostat only, use w/Mod M & N      
P2 Humidistat only, use w/Mod M & N      
P3 Humidistat & Thermostat w/Mod. M & N