| 4 |
Pressure Components rated for up to 300 PSI and for fresh water applicaitons. (standard) |
|
R2 |
Aux Relay 3 poles wired to terminals Customer to specify function |
| 5 |
Pressure Components rated for up to 600 PSI for fresh water applications |
|
R5 |
Includes NO & NC inst. contacts for load shed and time delay start |
| 6 |
Pressure Components rated for up to 300 PSI for salt water |
|
R7 |
Loadshed w/time delay for cont. w/ATS |
| 7 |
Pressure Components rated for up to 600 PSI for salt water |
|
S1 |
Pump Failure to Start Alarm Contacts & Indicator Light |
| E6 |
Paperless Pressure Recorder with RS232 for downloads. Records pressure data for last 7 day period |
|
S2 |
Pump Overload Alarm Contacts & Indicator Light |
| 3R |
Type 3R Enclosure for Outdoor, raintight aplications. Extra Gasketing on Doors and other openings to prevent entry of rain |
|
S3 |
Extra Phase Reversal Alarm Contacts for Remote Annunciation |
| 4P |
Type 4 Enclosure for Raintight applications. This powder coat painted steel enclosure resists the entry of rain and hose directed water. |
|
S4 |
Remote Low Pressure Alarm Contacts |
| 4X |
Type 4X Enclosure for Raintight and corrosive resistant applications. This 304 stainless steel enclosure resists the entry of rain and hose directed water. |
|
S5 |
Extra Pump Run NO & NC |
| 12 |
Type 12 Enclosure for Indoor, dust tight aplications. Extra Gasketing on Doors and other openings to prevent entry of Dust. |
|
S6 |
Extra Power Failure NO & NC |
| |
|
|
S7 |
Extra Power Available NO & NC |
| D1 |
Italian Nameplate |
|
S8 |
Low Voltage Alarm 90% NO & NC |
| D2 |
Dutch Nameplate |
|
S81 |
Low Reservior Light & NO & NC |
| D3 |
German Nameplate |
|
S82 |
High Reservior Light & NO & NC |
| D4 |
French Nameplate |
|
S84 |
Reserved |
| D5 |
Spanish Nameplate |
|
S85 |
Low Room Temp Light & NO & NC, (Includes Option V Room Temp Switch) |
| D6 |
Portugese Nameplates |
|
|
|
| |
|
|
|
|
| G |
Built In Alarm Panel provides |
|
V |
Pump Room Temperature Switch |
| H1 |
Pump Operating Light - LED Standard on all D-Series units built after 3/1/06 |
|
W |
Aux. Contact for remote indications of transfer switch position |
| H2 |
Other Light Functions, Customer to Specify function of light. |
|
W1 |
Wkly Test Timer w/drain Solenoid Valve |
| H3 |
Light package |
|
Y |
CE Marking |
| J, J21, J22 |
Lockout Relay - Interface relay to lock out a conroller from operation. Used with Low Suction Controls and Additive Pump Control options |
|
M & P2 |
Tropicalization |
| K |
Control Fuse, 1 Ampere fuse for control circuit being used outside of the controller enclosure. |
|
|
|
| |
Sequence Start (Standard) |
|
|
|
| L |
Series Pumping Controls |
|
|
|
| M |
Anti-Condensation Space Heaters with Transformer |
|
|
|
| N |
Space heater only 100 watt, 120 V |
|
|
|
| N1 |
Space heater only 100 watt, 240 V. |
|
|
|
| P1 |
Thermostat only, use w/Mod M & N |
|
|
|
| P2 |
Humidistat only, use w/Mod M & N |
|
|
|
| P3 |
Humidistat & Thermostat w/Mod. M & N |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|